Business finance availableFinance available Check if you qualifyCheck →
Home Machines Find Your Machine Safety & PPE Finance Hire Machine Business Launch Contact
Source extraction

D-series · DFS-series · 800 or 1,600 m³/h · price on enquiry

Laser cleaning fume extraction

Laser cleaning removes the coating; it does not make it disappear. Rust, paint, oxide, oil and residue leave the surface as dust, fume or vapour. We match the machine with source extraction around what you are removing, how much of it, and where the work is done.

Extraction is part of specifying the machine properly, not an afterthought. Final model, filtration and capture design are confirmed for your application.

LaserStrip® 800i Fume + VOC Extraction (DFS800i) in the LaserStrip matte-black finish

LaserStrip® 800i Fume + VOC Extraction (DFS800i). Each image starts from the supplier’s photograph of that exact model, refinished in the LaserStrip matte black with red on the existing accent areas. Cabinet, doors, castors, controls and connections are as photographed. Final production finish and labelling are confirmed on the written order.

The decision rule

Choose by what you remove, then by load

Choose the filtration family by what is being removed. Then choose 800 or 1,600 m³/h around the process load, the capture arrangement and the duty cycle. Do not choose an extractor on laser wattage alone.

D / D-i

Dry particulate route

Dry rust and scale mainly produce particulate, so a pulse-cleaned cartridge and HEPA system may be the right route. The D-series uses anti-static, flame-retardant cartridge filtration followed by an H14 HEPA stage, with automatic compressed-air pulse cleaning. Best for steel and iron rust, oxide scale and predominantly dry particulate.

DFS / DFS-i

Particulate + fume / VOC route

Painted, coated, oily or resinous surfaces can create a more complex mixture of fine particulate, fumes and odours, so the DFS-series adds activated carbon to the H14 final stage. It is the safer family to discuss for mixed commercial work: paint stripping, coated steel, oil and grease, resins. We confirm the final extractor and capture arrangement for the actual job before order.

Which extractor fits my work?

Contaminant first, then duty

The larger number is not automatically the better answer. Extraction is sized around the contaminant generation rate, working distance, hood or arm, duct losses and duty cycle. The 800 range is the compact route for lower-load, mobile or single-process work; the 1600 range gives more airflow capacity for heavier-duty and higher-load applications.

Extractor selection by contaminant and duty
What you are removing800 rangeLower load, mobile or single-process work1600 rangeHeavier duty, higher load
Dry rust, scale, oxide, dry metal particulateParticulate only800i Dry-Particulate (D800i)800 m³/h · 1 cartridge + H141600i Dry-Particulate (D1600i)1,600 m³/h · 2 cartridges + H14
Paint, powder coat, coatings, oil, grease, resin, mixed work, or not sureParticulate plus fumes and odours800i Fume + VOC (DFS800i)800 m³/h · 1 cartridge + H14 / activated carbon1600i Fume + VOC (DFS1600i)1,600 m³/h · 2 cartridges + H14 / activated carbon

Typical pairings: the Pro 300, Pro 300 15mJ and Pro 500 15mJ with an 800i unit; the Pro 3000 CW with a 1600i unit; a Duo with one extractor per machine when they work separately. Coatings that may contain lead or chromates need assessing before removal, and they can change the filtration and the controls around the job.

The LaserStrip extraction range

Four intelligent extractors

The intelligent “i” models are the public range. The four basic configurations remain available on enquiry and are in the technical table below. All prices on enquiry.

LaserStrip® 800i Dry-Particulate Extraction (D800i) in the LaserStrip matte-black finish

D-i · dry particulate

LaserStrip® 800i Dry-Particulate Extraction

Model D800i · price on enquiry

Best suited to: Dry rust, scale, oxide and metal particulate

Airflow
800 m³/h
Pressure
10,000 Pa
Blower
1,300 W
Dimensions
500 × 597 × 1,296 mm
Filtration
1 anti-static, flame-retardant polyester-fibre cartridge (Ø325 × 450 mm, quick-release) + H14 HEPA (406 × 406 × 70 mm)
Supply
220 V 50 Hz
Compressed air
External compressed-air supply required (pulse cleaning)
LaserStrip® 1600i Dry-Particulate Extraction (D1600i) in the LaserStrip matte-black finish

D-i · dry particulate

LaserStrip® 1600i Dry-Particulate Extraction

Model D1600i · price on enquiry

Best suited to: Higher-load dry particulate work

Airflow
1,600 m³/h
Pressure
10,000 Pa
Blower
2,600 W
Dimensions
670 × 794 × 1,570 mm
Filtration
2 anti-static, flame-retardant cartridges + H14 HEPA (496 × 596 × 70 mm)
Supply
220 V 50 Hz
Compressed air
External compressed-air supply required (pulse cleaning)
LaserStrip® 800i Fume + VOC Extraction (DFS800i) in the LaserStrip matte-black finish

DFS-i · particulate + fume / VOC

LaserStrip® 800i Fume + VOC Extraction

Model DFS800i · price on enquiry

Best suited to: Mixed work: paint, coatings, resin, oil and grease

Airflow
800 m³/h
Pressure
10,000 Pa
Blower
1,300 W
Dimensions
500 × 597 × 1,439 mm
Filtration
1 anti-static, flame-retardant polyester-fibre cartridge (Ø325 × 450 mm, quick-release) + combined H14 HEPA / activated-carbon stage (410 × 410 × 200 mm)
Supply
220 V 50/60 Hz
Compressed air
External compressed-air supply required (pulse cleaning)
LaserStrip® 1600i Fume + VOC Extraction (DFS1600i) in the LaserStrip matte-black finish

DFS-i · particulate + fume / VOC

LaserStrip® 1600i Fume + VOC Extraction

Model DFS1600i · price on enquiry

Best suited to: Higher-load mixed fume and coating work

Airflow
1,600 m³/h
Pressure
10,000 Pa
Blower
2,300 W high-negative-pressure
Dimensions
670 × 834 × 1,705 mm
Filtration
2 anti-static, flame-retardant cartridges + combined H14 HEPA / activated-carbon stage
Supply
220 V 50/60 Hz
Compressed air
Pulse cleaning; the compressed-air connection is confirmed on the production datasheet

Each image starts from the supplier’s photograph of that exact model, refinished in the LaserStrip matte black with red on the existing accent areas. Cabinet, doors, castors, controls and connections are as photographed. Final production finish and labelling are confirmed on the written order. Specifications are the supplier’s technical-sheet figures; exact model, options, compressor duty and electrical requirements are confirmed on your written quotation.

What the “i” adds

Monitoring and control, built in

The “i” models add the manufacturer’s intelligent monitoring and control platform, including real-time airflow and negative-pressure information, filter status functions, connectivity and optional air-quality sensing. Exact sensors and communications are confirmed on the quotation.

  • A larger industrial touch control centre
  • Filter-health status and replacement warnings
  • I/O, RS-485 and supplier-stated Wi-Fi connectivity for workshop integration
  • Optional PM2.5, VOC, ozone, odour and HCl sensing
  • Supplier-stated temperature and humidity safety shutdown
  • Software updates by TF card

Technical comparison

All eight configurations

Supplier technical-sheet figures. The basic D and DFS configurations are available on enquiry.

Extractor configurations: airflow, pressure, blower, supply, dimensions, filtration and compressed air
ModelRouteAirflowPressureBlowerSupplyDimensionsFiltrationRange
D / D-i: dry particulate
D800iDry rust, scale, oxide and metal particulate800 m³/h10,000 Pa1,300 W220 V 50 Hz500 × 597 × 1,296 mm1 anti-static, flame-retardant polyester-fibre cartridge (Ø325 × 450 mm, quick-release) + H14 HEPA (406 × 406 × 70 mm)Intelligent range
D800Dry particulate800 m³/h10,000 Pa1,300 W220 V 50 Hz, 9 A500 × 597 × 1,296 mm1 cartridge + H14 HEPA (406 × 406 × 70 mm); pulse backflushOn enquiry
D1600iHigher-load dry particulate work1,600 m³/h10,000 Pa2,600 W220 V 50 Hz670 × 794 × 1,570 mm2 anti-static, flame-retardant cartridges + H14 HEPA (496 × 596 × 70 mm)Intelligent range
D1600Dry particulate1,600 m³/h10,000 Pa2,600 W220 V 50 Hz670 × 794 × 1,570 mm2 cartridges + H14 HEPA (496 × 596 × 70 mm); one capture armOn enquiry
DFS / DFS-i: particulate plus fume and VOC
DFS800iMixed work: paint, coatings, resin, oil and grease800 m³/h10,000 Pa1,300 W220 V 50/60 Hz500 × 597 × 1,439 mm1 anti-static, flame-retardant polyester-fibre cartridge (Ø325 × 450 mm, quick-release) + combined H14 HEPA / activated-carbon stage (410 × 410 × 200 mm)Intelligent range
DFS800Mixed fume / VOC800 m³/h10,000 Pa1,300 W220 V 50 Hz, 9 A500 × 597 × 1,439 mm1 cartridge + combined H14 HEPA / carbon (410 × 410 × 200 mm)On enquiry
DFS1600iHigher-load mixed fume and coating work1,600 m³/h10,000 Pa2,300 W high-negative-pressure220 V 50/60 Hz670 × 834 × 1,705 mm2 anti-static, flame-retardant cartridges + combined H14 HEPA / activated-carbon stageIntelligent range
DFS1600Higher-load mixed fume / VOC1,600 m³/h10,000 Pa2,600 W220 V 50 Hz, 18 A670 × 834 × 1,705 mm2 cartridges + combined H14 HEPA / carbon (500 × 600 × 200 mm)On enquiry

Filters

  • Cartridges: anti-static, flame-retardant, coated polyester fibre, Ø325 × 450 mm, quick-release.
  • H14 HEPA: supplier-stated ≥99.997% at 0.3 micron. That is a figure for the filter element, not a guarantee of total system capture.
  • DFS final stage: H14 HEPA combined with activated carbon, intended to adsorb certain odours and VOCs. Suitability depends on the contaminant and the loading.

Before you order

  • Capture decides performance: hood or arm position, airflow and the process matter as much as the filter.
  • All models use automatic pulse cleaning; the external compressed-air supply and duty are confirmed on the quotation.
  • Manufacturer warranty: one year on the unit. Filters are consumables and are not covered.
  • Not in the extractor price: the compressor for pulse cleaning and respiratory protection, both quoted separately once duty and filtration are confirmed, and replacement filters, which are consumables. Your COSHH assessment and LEV duties stay with you as the employer.

Why it matters

Capture at source is the control that does the most

A laser leaves no blast media, but the layer it removes ends up in the operator’s breathing zone as fume and fine particulate unless it is captured close to where the beam meets the surface. Under COSHH, employers have to assess and control that exposure; HSE publishes guidance on local exhaust ventilation (LEV). Respiratory protection can be an additional control where the assessment requires it, never a substitute: see safety and PPE.

Matched to the machine, in every package

  • Pro 300 15mJ and Pro 500 15mJ: DFS800i for mixed work, D800i for genuinely dry rust and scale
  • Pro 3000 CW: DFS1600i for coatings and fume, D1600i for predominantly dry rust and scale
  • Duo: one extractor per machine when they work separately; the mixed-work default is DFS800i + DFS1600i

Safety, extraction and your site

A Class 4 laser needs controls, not just a machine

Every machine in the range is a Class 4 laser. Before you buy, we talk through what running one means on your site, and anything that needs to be in place before the first job.

What has to be in place

  • A laser risk assessment and a controlled working area, with signage and access control while the laser is in use
  • Laser safety eyewear matched to the laser (1064nm (pulsed) or 1080nm (CW)) for the operator and anyone inside the area, plus protective clothing and respiratory protection where the assessment requires it: laser cleaning safety and PPE
  • Fume and particulate capture at source. Laser cleaning turns the removed layer into fume and fine dust, and coatings can contain lead, chromates or other hazardous substances, which need assessing before they are removed at all
  • Trained, competent operators and a written safe system of work, with a designated Laser Safety Officer considered for Class 4 use: LSO training

What we look at with you

  • What is being removed, and whether the coating needs testing for hazardous content first
  • Where the work happens: workshop, production line or site, indoors or out
  • Power supply and the space the machine needs
  • The extraction and capture arrangement that suits the job: laser cleaning extraction

Laser use at work falls under the Control of Artificial Optical Radiation at Work Regulations 2010, and fume under COSHH. See HSE guidance on non-ionising radiation. Responsibility for your risk assessments, controls and competent operation stays with you as the employer.

Need specialist laser-safety training? Ask about individual and company options. Laser Safety Officer training is arranged separately from the operator familiarisation at handover, and is available whether or not you buy your machine from us.

LSO training options →

Extraction

Frequently Asked Questions

Do I need fume extraction for laser cleaning?+

In practice, yes. Laser cleaning removes the coating, it does not make it disappear: rust, paint, oxide, oil and residue leave the surface as dust, fume or vapour. Capturing it at source is the primary control, alongside the laser risk assessment, and paints can contain lead, chromates or other hazardous substances that need assessing before they are removed at all.

What is the difference between the D and DFS extractors?+

The D-series is a dry particulate route: pulse-cleaned, anti-static, flame-retardant cartridge filtration followed by an H14 HEPA stage, for rust, scale and dry metal particulate. The DFS-series adds activated carbon to the final stage, for painted, coated, oily or resinous work that creates fine particulate together with fumes and odours. DFS is the safer family to discuss for mixed commercial cleaning; the final choice follows a review of the contaminant and the capture arrangement.

Should I choose 800 or 1600 m³/h?+

Not by laser wattage alone, and the larger number is not automatically better. Extraction is sized around how much material is being generated, the working distance, the hood or arm, duct losses and the duty cycle. The 800 range is the compact route for lower-load, mobile or single-process work; the 1600 range gives more airflow capacity for heavier-duty, higher-load applications.

What does the "i" add?+

The intelligent models add the manufacturer’s monitoring and control platform: real-time airflow and negative-pressure information, filter status and replacement warnings, connectivity (I/O, RS-485 and supplier-stated Wi-Fi) and optional air-quality sensing. The exact sensors and communications are confirmed on the quotation.

Do the extractors need compressed air?+

Yes, for automatic pulse cleaning of the cartridges: the supplier sheets state an external compressed-air supply for the D800i, D1600i and DFS800i. The DFS1600i compressed-air connection is confirmed on the production datasheet. Compressor duty is confirmed on your quotation.

Does a 99.997% H14 filter mean the fume is controlled?+

No. H14 at 99.997% (0.3 micron) is the supplier’s stated figure for the filter element. It says nothing about how much fume reaches the filter in the first place. Hood or arm position, airflow and the process decide capture, which is why we review the capture arrangement for the actual job.

How much does an extractor cost?+

Extraction is priced on enquiry and quoted with your machine or package, because the model, filtration and capture arrangement follow from the application. The manufacturer’s warranty is one year on the unit; filters are consumables and are not covered.

Machine selection

Tell us what you need to extract.

Tell us what you need to clean and we’ll recommend the right LaserStrip system. Describe the material, what is on it, how much of it there is and where the work happens. We come back within one business day with a recommendation and, when it fits, a written quotation itemising the machine, options, delivery, commissioning and training.

Response
Within one business day
About the work, so we can specify the whole system
Also price:

Photos, a safety data sheet (SDS) or coating details help us specify the right extraction and PPE. Reply to our email with them, or send them to hello@laserstrip.co.uk.

What’s in Business Launch →
Individual and company options →

We respond within one business day. Your details are never shared.